Requirements versus design

Accelerator 

Spallation target 

Subcritical core 

 

Fuel 

 

Engineering 

 

Subcriticality 

 

Power 

The subcriticality level

To achieve inherent safety, the subcriticality level of the core is set at 0.95; the level of a classical fuel storage. In this way, we have a margin with respect to criticality in normal and accidental conditions.